| Author |
Message |
GMartin
Joined: Feb 5, 2010 Posts: 308
|
Posted: Dec 15, 2015 6:48 PM Post subject: f_numeric display |
|
Jarek,
I am finishing up a design for Infra Low Frequency style training. One last thing I would like to do is have a float numeric display read out the frequency being trained. The float numericdisplay works well down to .001 then shows something like .OOO98E. Is there a way to have the value lower than than that display. I think is very rare that training would go that low but I would like to have the readout for anyone who wanted.
Thanks
George |
|
 |
jarek
Joined: Oct 22, 2007 Posts: 1073
|
Posted: Dec 15, 2015 8:08 PM Post subject: |
|
Float number with 'E' is a valid format, but yes, I agree it is not very easy to read.
I will try to improve it tonight. |
|
 |
GMartin
Joined: Feb 5, 2010 Posts: 308
|
Posted: Dec 15, 2015 8:45 PM Post subject: |
|
I figured it was a valid value. Just hoping for more readability not a major issue
Thanks
George |
|
 |
jarek
Joined: Oct 22, 2007 Posts: 1073
|
Posted: Dec 16, 2015 12:55 AM Post subject: |
|
| This should be improved starting from the version 3.244 |
|
 |
GMartin
Joined: Feb 5, 2010 Posts: 308
|
Posted: Dec 16, 2015 1:31 AM Post subject: |
|
Jarek
Thanks for the swift response
george |
|