Main siteMain site  ForumForum  ForumSearch  Private messageEmail contact  RegisterRegister  Log inLog in 
Topic: Vilistus Device
Reply to topic
Author Message
sahar



Joined: Nov 29, 2013
Posts: 2

PostPosted: Nov 24, 2014 11:20 PM    Post subject: Vilistus Device

Jarek,

I saw that you have added an option (Mode) to vilistusdevice properties. Could you please explain this new option?

Best
jarek



Joined: Oct 22, 2007
Posts: 1073

PostPosted: Nov 24, 2014 11:33 PM    Post subject:

This is a minor change and only about signal ranges. The default (EEG) mode makes the element behaving as before. The RAW mode will set positive range 0..1023, which is more appropriate for other types of signals like GSR.

I updated the manual:

http://www.bioera.net/manual.html#_Toc403982888
sahar



Joined: Nov 29, 2013
Posts: 2

PostPosted: Nov 25, 2014 4:07 AM    Post subject:

Thanks for the quick response