Topic: Signal range in replayed files
Reply to topic
Author Message
Marius



Joined: Jun 10, 2013
Posts: 51

PostPosted: Sep 12, 2013 8:17 PM    Post subject: Signal range in replayed files

Hi Jarek,

when a XDF file is played BioEra sees automatically if the file contains negative values or not, and sets digtal min/max values accordingly in all the following elements. (to -1/1 or 0/1)

This lead to problems because once these properties are set, they do not change anymore when a new XDF file is chosen.
If an only-positive file is chosen first, and a file with positive and negative values afterwards, the negative values will not be displayed because the oscilloscopes have been set to digital min 0 and stay that way

Can you do something about this?
jarek



Joined: Oct 22, 2007
Posts: 1073

PostPosted: Sep 12, 2013 9:03 PM    Post subject:

If you change to a file with different signal properties (like what you described), you should always reinitialize the whole design. That reinitialization (ReinitAll) should update those properties in all elements.