Main siteMain site  ForumForum  ForumSearch  Private messageEmail contact  RegisterRegister  Log inLog in 
Topic: Increasing Reward/Inhibit Bands
Reply to topic
Author Message
shadowlore



Joined: Jul 7, 2008
Posts: 8

PostPosted: Aug 3, 2008 9:36 PM    Post subject: Increasing Reward/Inhibit Bands

Hi

I need to do some EEG training to down train 20Hz-32Hz and 4Hz - 10Hz.

I realise the default range is -1.5Hz and +1.5Hz from the selected frequency.

I would need to adjust this to -3Hz/+3Hz and also -6Hz/+6Hz.

What do you need to change on the design to achieve this?

Regards
Adam

jarek



Joined: Oct 22, 2007
Posts: 1075

PostPosted: Aug 3, 2008 9:56 PM    Post subject:

Adam,

1. open nested design \"Reward/Inhibit..\": right click on it and select LoadNestedDesign.
2. Open properties of the C_Mixer elements and change in each from 1.5 to whatever you like, this will be the inhibit filter. Save the design.
3. To change reward filter open the \"Nested\" design the same way as before, and change C_Mixer properties in there as before. Save the design.

Hope this is clear enough.

Jarek
Reply to topic